Battery powered
15.0 V, 1500 mAh on-board cell. No console, no cable, no capital equipment — the morcellator is the system.
A battery-powered disposable morcellator engineered for laparoscopic gynecologic procedures — purpose-built for hysterectomy and myomectomy. Sterile from the first incision. Discarded after the last.
Battery-powered cutting and tissue extraction in a single pistol-grip instrument. Integrated trocar and obturator. Pre-configured "Safety Guard," "Cut 1" (peel) and "Cut 2" (core) modes.
01
02
03
04
05
06
07
08
Electrical and thermal isolation along the cutting tube.
Threaded cap controlling the coreguard depth setting.
Locks the trocar between Safety Guard, Cut 1 and Cut 2 positions.
Ergonomic pistol grip housing the 15.0 V battery and electronics.
Single-action activation of the rotating cutting blade.
Rotating tubular blade — 1000 RPM peel and core action.
Adjustable barrier preventing over-travel of the cutting tip.
Inserted fully prior to trocar placement through the abdominal wall.
15.0 V, 1500 mAh on-board cell. No console, no cable, no capital equipment — the morcellator is the system.
Tubular peel-and-core blade with two distinct positions — "Cut 1" for peeling, "Cut 2" for coring tissue.
Single sterile-barrier system with protective outer packaging. Validated ethylene-oxide cycle. Three-year shelf life.
No reprocessing, no resterilization, no cross-contamination risk. Each device retires immediately after the procedure.
The obturator and trocar arrive pre-paired. Inserted under direct visualization through a 12–14 mm incision.
Conforms to IEC 60601-1-2 : 2014 + AMD1 : 2020 EMC. Type BF applied part. Latex-free. RX Only.
Laparoscopic removal of the uterus, with morcellation of de-vascularized, dissected tissue under direct visual control.
Removal of uterine fibroids, with controlled coring ("Cut 2") and peeling ("Cut 1") of de-vascularized myomas.
Per FDA guidance (Dec 30, 2020), laparoscopic power morcellators are contraindicated for removal of uterine tissue containing suspected fibroids in patients who are post-menopausal or over 50, or who are candidates for en-bloc tissue removal through the vagina or via a mini-laparotomy incision. Tissue must be devascularized and dissected before morcellation. Not for use where malignancy is known or suspected.
RX Only · For use by trained surgical professionals.